Loading
NIST-Traceable Precision Calibration

Pressure Calibration Services

NIST-traceable calibration for digital and analogue pressure gauges, pressure sensors, transducers, barometers, and manometers. Precision you can trust for critical pressure measurement applications.

Why Pressure Calibration Matters

Accurate pressure measurement is critical in process control, quality assurance, safety systems, and manufacturing operations. Incorrect pressure readings can lead to product defects, equipment damage, safety hazards, and regulatory non-compliance. Regular NIST-traceable calibration ensures your pressure instruments deliver consistent, reliable measurements across their entire range.

±0.025%
Accuracy Available
NIST
Traceable Standards
ISO 17025
Compliant Process
48HR
Fast Turnaround

Pressure Equipment We Calibrate

Comprehensive calibration services for all types of pressure measurement devices

Digital Pressure Gauges

Precision calibration of digital pressure gauges used in process control, quality assurance, and laboratory applications.

  • Digital test gauges
  • Digital pressure indicators
  • Electronic pressure gauges
  • Portable pressure calibrators
  • Precision digital manometers
  • Data-logging pressure gauges
  • Wireless pressure transmitters

Analogue Pressure Gauges

Expert calibration of mechanical pressure gauges for industrial, commercial, and laboratory use.

  • Bourdon tube pressure gauges
  • Diaphragm pressure gauges
  • Compound gauges (vacuum/pressure)
  • Differential pressure gauges
  • Test gauges (dial indicators)
  • Pneumatic gauges
  • Hydraulic pressure gauges

Pressure Sensors & Transducers

Calibration of pressure sensors and transducers used in automated control systems and data acquisition.

  • Pressure transmitters (4-20mA)
  • Strain gauge pressure sensors
  • Piezoelectric pressure sensors
  • Capacitive pressure sensors
  • Differential pressure transmitters
  • Absolute pressure transducers
  • Gauge pressure transmitters

Barometers & Atmospheric

Precision calibration of barometric pressure instruments for meteorological and laboratory applications.

  • Digital barometers
  • Aneroid barometers
  • Mercurial barometers
  • Barometric pressure sensors
  • Weather station instruments
  • Altitude measurement devices

Vacuum Gauges & Controllers

Expert calibration of vacuum measurement instruments for industrial and laboratory vacuum systems.

  • Pirani vacuum gauges
  • Thermocouple vacuum gauges
  • Capacitance manometers
  • Cold cathode gauges
  • Digital vacuum gauges
  • Vacuum pressure transducers

Specialized Pressure Devices

Calibration of specialized pressure measurement equipment for unique applications and industries.

  • Deadweight testers
  • Pressure calibrators
  • Manometers (U-tube, inclined)
  • Pressure switches
  • Pressure recorders
  • Sanitary/hygienic pressure sensors
  • High-pressure transducers

Our Calibration Process

Multi-point testing with NIST-traceable standards for complete accuracy assurance

1

Receiving & Inspection

Each device is logged into our system with unique identification. Visual inspection documents condition, identifies damage, and records nameplate data.

2

As-Found Testing

We test your instrument at multiple points across its full range using our NIST-traceable pressure standards. This documents the device's accuracy before calibration.

3

Adjustment & Calibration

Devices are adjusted to meet manufacturer specifications or customer requirements. Zero and span adjustments are made as needed to bring instruments within tolerance.

4

As-Left Testing

After calibration, we re-test at the same pressure points to verify accuracy. This ensures the device meets required specifications across its entire range.

5

Certification & Documentation

Complete calibration certificates include as-found and as-left data, uncertainty calculations, traceability information, environmental conditions, and pass/fail status.

6

Labeling & Return

Devices are marked with calibration date and due date labels. Complete documentation is provided digitally and in print, and instruments are securely packaged for return.

Compliance & Standards

Pressure Standards

We adhere to internationally recognized standards for pressure calibration:

  • ANSI/ISA-51.1: Process instrumentation
  • ASME B40.100: Pressure gauges and indicators
  • ISO 1000: SI units and recommendations
  • ASTM E1137: Industrial platinum RTDs
  • Multi-point calibration protocols
  • Hysteresis and repeatability testing

NIST Traceability

Every calibration is traceable to the National Institute of Standards and Technology:

  • Primary standards calibrated at NIST
  • Deadweight tester standards
  • Complete uncertainty analysis
  • Documented traceability chain
  • Comprehensive calibration certificates
  • ISO/IEC 17025 compliant processes

Industry Applications

Our pressure calibration services support critical operations across multiple industries:

  • Oil & Gas Production
  • Chemical Processing
  • Pharmaceutical Manufacturing
  • Power Generation
  • HVAC Systems
  • Aerospace & Aviation
  • Food & Beverage Processing
  • Water Treatment

Calibration Intervals

Recommended calibration frequency depends on usage, accuracy requirements, and criticality:

  • Critical Process Control: Quarterly
  • Daily Use: Every 6 months
  • Regular Use: Annually
  • Light Use: Every 2 years
  • Reference Standards: Annually
  • After Damage/Over-pressure: Immediately

Ensure Accurate Pressure Measurements

Don't risk process control failures, safety hazards, or regulatory non-compliance with uncalibrated pressure instruments. Schedule your NIST-traceable pressure calibration today.

Fast turnaround available • On-site calibration for large installations